industrial cooling

Cooling systems for logistics halls, productions, storage sites...

In the industry, it is a must to use cooling systems for most diverse processes. The area of application is varied and possibly spread over several locations of a large production. Here, the MultiChillerKit offers both a solution for larger applications and the use at different locations due to the decentralised installation of the devices. Several applications can be coupled with each other via an overall system and only a system for all applications is created.

air conditioning

Air conditioning +10°C bis +30°C

normal cooling

Normal cooling 0°C bis +20°C

intensive cooling / freezing

Intensive cooling -20°C bis +20°C

Logistics centre

Normal cooling and air conditioning using the example of a logistics centre

Today, cooling for all kinds of goods is the standard for the quality assurance. However, workplaces are also air-conditioned today in order to achieve an effective way of working. With the MultiChillerKit, both the requirements for air conditioning can be met with one overall system and refrigeration rooms can be operated additionally.

logistic cooling
note
Chiller
note
drycooler
note
normal cooling
note
normal cooling
note
air conditioning
18°C
6°C
8°C

 

Components

Chiller
chiller
6 x 300kW
Normal Cooling
normal-cooling
2 x 50kW
Dry Cooler
dry-cooler
1 x 400kW
Air Conditioning
air-cooling
1 x 250kW

Process cooling

Normal cooling and air conditioning using the example of an industrial plant

Process cooling can be found in the most diverse applications. Due to the flexibility of the MultiChillerKit, extensions can be made at any time without changing the system.

production
note
Chiller
note
drycooler
note
process cooling
note
process cooling
note
air conditioning
18°C
6°C
8°C

 

Components

Chiller
chiller
6 x 300kW
Dry Cooler
dry-cooler
1 x 400kW
Air Conditioning
air-cooling
1 x 150kW
Production
production
2 x 150kW

computer centre

Air conditioning using the example of a computer centre

The need for secure and high-speed data is constantly increasing. In order to secure the server performance, permanent and redundant cooling is required. With the MultiChillerKit, computer centres can be operated effectively and with the highest possible security.

data center cooling
note
Chiller
note
drycooler
10°
10°

 

Components

Chiller
chiller
4 x 120kW
Dry Cooler
dry-cooler
1 x 160kW